Communities

Writing
Writing
Codidact Meta
Codidact Meta
The Great Outdoors
The Great Outdoors
Photography & Video
Photography & Video
Scientific Speculation
Scientific Speculation
Cooking
Cooking
Electrical Engineering
Electrical Engineering
Judaism
Judaism
Languages & Linguistics
Languages & Linguistics
Software Development
Software Development
Mathematics
Mathematics
Christianity
Christianity
Code Golf
Code Golf
Music
Music
Physics
Physics
Linux Systems
Linux Systems
Power Users
Power Users
Tabletop RPGs
Tabletop RPGs
Community Proposals
Community Proposals
tag:snake search within a tag
answers:0 unanswered questions
user:xxxx search by author id
score:0.5 posts with 0.5+ score
"snake oil" exact phrase
votes:4 posts with 4+ votes
created:<1w created < 1 week ago
post_type:xxxx type of post
Search help
Notifications
Mark all as read See all your notifications »
Q&A

Voltage of tank circuit is invalid

+0
−2

In a previous question we found that for a critically damped oscillation:

$$ I(t) = 2 t e^{-0.5 t} $$

But if we integrate to find the voltage through the capacitor:

$$ V_{CO} + \frac{1}{C} \cdot \int_0^t{I(t)}dt $$

the integral is always a positive value which doesn't make any sense since the capacitor is being discharged.

What am I doing wrong here? Help appreciated!

History
Why does this post require moderator attention?
You might want to add some details to your flag.
Why should this post be closed?

1 comment thread

When it is critically damped, there is not oscillation. (1 comment)

1 answer

+4
−2

You need to be more careful.

First, you should have been able to see for yourself that the first equation isn't written right. I'll assume the whole "-0.5t" is the exponent of e. You were too sloppy to notice, or too lazy to fix it. Either way, it's really rude to the volunteers here. That's what the downvote is for.

Second, pay attention to the sign. The top equation always yields a positive result for positive values of t. Obviously integrating that will also yield a positive result. You have to decide which way is positive current flow, and therefore positive voltage, and stick to it. In this case, a diagram of the circuit with I and V clearly labeled would have probably caused you to see the mistake for yourself.

Taking extra care to be meticulous may seem like a waste of time, but is actually a time saver in the long run. You need to learn that sooner than later. In the real world, you don't get partial credit because your mistake was "only" flipping a sign. If it doesn't work, it doesn't work, and it's on you.

There is no place for sloppiness in engineering. Grow up.

History
Why does this post require moderator attention?
You might want to add some details to your flag.

1 comment thread

@#36396 I dont know how to use LaTeX and I used one of the online editors I found.I tried to find an ... (5 comments)