Communities

Writing
Writing
Codidact Meta
Codidact Meta
The Great Outdoors
The Great Outdoors
Photography & Video
Photography & Video
Scientific Speculation
Scientific Speculation
Cooking
Cooking
Electrical Engineering
Electrical Engineering
Judaism
Judaism
Languages & Linguistics
Languages & Linguistics
Software Development
Software Development
Mathematics
Mathematics
Christianity
Christianity
Code Golf
Code Golf
Music
Music
Physics
Physics
Linux Systems
Linux Systems
Power Users
Power Users
Tabletop RPGs
Tabletop RPGs
Community Proposals
Community Proposals
tag:snake search within a tag
answers:0 unanswered questions
user:xxxx search by author id
score:0.5 posts with 0.5+ score
"snake oil" exact phrase
votes:4 posts with 4+ votes
created:<1w created < 1 week ago
post_type:xxxx type of post
Search help
Notifications
Mark all as read See all your notifications »
Q&A

how to figure out the max power of a transformer?

+1
−1

I have a MOT that is rated 220V-50Hz only and i need to know its maximum operating power i tried to google the reference number but unable to find anything about its power, so how to figure out the max power?

MOT

Edit: so here what I did, I removed the secondary winding of the high voltage and the third of three loops and replaced it with a group of four wires together and made two loops with them, then I measured the main and found ~235 volts then connected the microwave transformer to its board, which is just a filter(A resistor of 1Mohm in parallel, a polyester capacitor of 220nF in parallel, a coil with two inputs two output series) then connected to main the secondary winding showed 1.99 volts then used my clamp meter and short cut the secondary for five seconds each time, the current measured was ~350 amperes.
So law ohm says power is voltage multiplied by the current:
P= 2×350
P= 700
Then to find primary coil current laws ohm says current equal power divided by voltage:
A=700÷235
A=2.98
Now I have three issues to resolve;
1- the inrush current.
2- cable size European norm.
3- the heat generated is transferred to the cable.

History
Why does this post require attention from curators or moderators?
You might want to add some details to your flag.
Why should this post be closed?

2 comment threads

Inexplicable description of what you tried (2 comments)
What's a "MOT"? (3 comments)

2 answers

+2
−0

You best source of information is boilerplate on the part itself. you have that but all there is is a part number and the design voltage.

Your next best information is the boilerplate on the appliance itself, you seem to have lost that.

So back to the part boilerplate.

"GAL-700E-1S" that's some sort of part number doing a search on that suggests the brand "Galanz" so possibly from a Galanz microwave oven.

Looking at the Galanz product line-up I find a 700W microwave oven, This is quite possibly coincidence but engineers tend to try to make things easy to remember. so there's a good chance that this transformer if from a 700W microwave oven. so 700VA or slightly more is a good bet.

The engineers who design transformers tend to try to reduce the amount of material used as far as possible, so if if you can find another 700VA transformer it will likely weigh the same amount and be the same size.

History
Why does this post require attention from curators or moderators?
You might want to add some details to your flag.

0 comment threads

+1
−1

If there isn't a VA rating on the label or published in a reliable source, then you have to guess. There are several clues that can be used:

  1. Look at the size of the primary wires. That gives you an upper bound on the primary current. You know this is meant for 220-240 V systems, so between these you get an upper bound on the input power.

    This is so unreliable as to not be worth bothering with for a "small" transformer. Your transformer looks big enough to be meant to handle enough power, and therefore input current, so that the wire won't be grossly oversized.

  2. Put a fixed sine wave in at the rated frequency (50 Hz in your case) and see what comes out the secondary open-loop. Do not give it the full rated input voltage. In this case, I'd use a variac to drive the primary without about 50 V. Measuring the open-circuit output voltage then gives you the transformer ratio.
  3. Knowing the secondary voltage from #2, use the method from #1 to get an upper limit of power.
  4. Use the setup from #2 and see what the output short-circuit current is. I'd start with the variac at 0, then slowly crank it up to get a meaningful output current, but at well below intended power. The transformer should be able to handle 10% of the rated input voltage with the secondary shorted indefinitely.

    By measuring the open-circuit voltage and the short-circuit current, you can get an idea of the impedance of the whole unit as seen looking into the secondary. The maximum possible output power is ¼ the open-circuit voltage times the short-circuit current at the full rated input voltage. That is a guaranteed not to exceed value, and not likely the intended operating power.

  5. Take a guess on power dissipation based on size, then work backwards to intended operating power based on a guess of efficiency.

    It's hard to get the size from your picture, but if it's fist-sized, then it can probably handle 10 W dissipation without damage. You can actually try different dissipations with the variac setup and shorted secondary to see how much power gets it too hot. Remember that the windings inside will be hotter than the outside of the bulk iron. I wouldn't let the outside get hotter than what you can hold your hand on indefinitely.

    Your transformer doesn't look particularly high tech. It has the look of cost being a higher priority than efficiency. I'd guess 80% efficiency at best, probably lower.

  6. Consider how this transformer was used, if you have that. Did it come from a 1960s television (an old TV transformer would have multiple secondaries, this is an example only)? Any such appliance would have a maximum line current or power shown on the nameplate by the line cord entrance. Especially for a consumer item that was designed for low price, the transformer will be just barely able to handle the maximum input power.

    Even if the specific appliance isn't available anymore, a 1960 TV is unlikely to draw more than 200 W, for example.