Is it always necessary to use the ground terminal of the oscilloscope probe?

+3
−0

Assume my oscilloscope is grounded, and the DUT is grounded as well (earth ground). I am using a standard 10 Mohm impedance 1:10 passive probe. So, the ground terminal of the probe is in fact connected to earth through the oscilloscope chassis.

Is there any reason to connect the ground tip of the probe to the ground of the DUT?

Why does this post require moderator attention?
You might want to add some details to your flag.
Why should this post be closed?

1 comment

You can easily answer this by not connecting the probe ground to the DUT and measure something, then connect the ground and measure again. The signal that looks like crap is the one that you don't want. Lundin‭ 3 months ago

2 answers

+5
−0

Yes, you should connect the scope probe ground to the circuit ground near where you are probing.

The unit under test (UUT) and the scope may have their grounds connected, but that is via a round-about path. This causes problems:

  1. The ground path can have significant impedance at high frequencies. Put another way, no, the grounds aren't really connected at high frequencies.
  2. The loop can pick up noise via inductive coupling. Any voltage induced in the loop will show up on the trace directly as a signal. This can be from the 50 or 60 Hz power line frequency, but also from spikes on the power line, radio transmissions, etc.
  3. There can be ground offset between two different branches of the power distribution network. This offset again shows up on the trace like a signal.

An easy way see this for yourself is to connect just the probe tip to the ground of UUT, with the scope ground clip unconnected. In theory you should see a flat line at 0 V, but you won't. Everything you see there is noise that will be added to any other UUT signals you look at without grounding the scope probe. Usually this noise is enough to be visible even at something like 1 V/div. If you happen to be in an unusually quiet environment, crank up the gain and you'll see it. Note that anything you see here is noise due to bad scope probe grounding. If your theory were correct, you'd always see flat 0 V, but you won't.

Now hold the grounding clip against the UUT ground nearby, and watch most of the noise disappear. The same experiment works with any DC voltage, like a power supply output. In that case you may have to switch to AC coupling so that the DC level doesn't force the trace off the screen before the gain is enough to seen the noise. You'll see a solid difference between probe ground connected to the UUT and not.

Why does this post require moderator attention?
You might want to add some details to your flag.

2 comments

@Olin Lathrop. Thank you for this nice answer. I would like to precise my understanding (I don't think this is worthy a new question since the answer may be more or less "yes" or "no"). So, a measurement with a standard probe could be seen as the juxtaposition of a DC measurement with respect to the oscilloscope ground, and a differential AC measurement at the points where the probe head terminals are connected? is my understanding correct? coquelicot‭ 3 months ago

Great answer by Olin. I think the answer does raise the question, why is the oscilloscope chassis and probe common being tied to earth ground if the earth ground is not benefiting the measurement? I think the answer is that the earth ground is there for electrical shock safety (same reason we electrically bond the chassis of other electrical products to earth ground). CuriousDavid‭ 25 days ago

+4
−0

To add to Olin's excellent answer, if you were probing on a digital IO line in order to view a fast changing signal, without the local ground clip (or spring) grounded close to where you make the measurement, you would, in effect, be adding an antenna to that IO line and causing interference to other parts of the circuit and even other circuits in the same vicinity. The signal captured by your o-scope would contain all-manner of unwanted artefacts as well.

Why does this post require moderator attention?
You might want to add some details to your flag.

1 comment

I like how Andy’s answer also considers the impact of the probe on the system. CuriousDavid‭ 25 days ago

Sign up to answer this question »

This community is part of the Codidact network. We have other communities too — take a look!

You can also join us in chat!

Want to advertise this community? Use our templates!